]> ncurses.scripts.mit.edu Git - ncurses.git/blobdiff - man/tput.1
ncurses 5.5
[ncurses.git] / man / tput.1
index 84b64b2588a19c82091773e8742171361063d9a7..b12385e18f5bb28e454a177373b160a94ce6f8d4 100644 (file)
@@ -1,6 +1,6 @@
 '\" t
 .\"***************************************************************************
-.\" Copyright (c) 1998 Free Software Foundation, Inc.                        *
+.\" Copyright (c) 1998-2004,2005 Free Software Foundation, Inc.              *
 .\"                                                                          *
 .\" Permission is hereby granted, free of charge, to any person obtaining a  *
 .\" copy of this software and associated documentation files (the            *
 .\" authorization.                                                           *
 .\"***************************************************************************
 .\"
-.\" $Id: tput.1,v 1.12 1999/01/24 02:44:26 Jeffrey.C.Honig Exp $
+.\" $Id: tput.1,v 1.22 2005/01/08 17:44:26 tom Exp $
 .TH tput 1 ""
-.ds d @DATADIR@/terminfo
-.ds n 5
+.ds d @TERMINFO@
+.ds n 1
 .SH NAME
-\fBtput\fR - initialize a terminal or query terminfo database
+\fBtput\fR, \fBreset\fR - initialize a terminal or query terminfo database
 .SH SYNOPSIS
 \fBtput\fR [\fB-T\fR\fItype\fR] \fIcapname\fR [\fIparms\fR ... ]
 .br
 .br
 \fBtput -S\fR  \fB<<\fR
 .br
+\fBtput -V\fR
+.br
 .SH DESCRIPTION
 The \fBtput\fR utility uses the \fBterminfo\fR database to make the
 values of terminal-dependent capabilities and information available to
 the shell (see \fBsh\fR(1)), to initialize or reset the terminal, or
-return the long name of the requested terminal type.  \fBtput\fR
-outputs a string if the attribute (\fIcap\fRability \fIname\fR) is of
-type string, or an integer if the attribute is of type integer.  If
-the attribute is of type boolean, \fBtput\fR simply sets the exit code
-(\fB0\fR for TRUE if the terminal has the capability, \fB1\fR for
-FALSE if it does not), and produces no output.  Before using a value
-returned on standard output, the user should test the exit code
-[\fB$?\fR, see \fBsh\fR(1)] to be sure it is \fB0\fR.
+return the long name of the requested terminal type.
+The result depends upon the capability's type:
+.RS
+.TP 5
+string
+\fBtput\fR writes the string to the standard output.
+No trailing newline is supplied.
+.TP
+integer
+\fBtput\fR writes the decimal value to the standard output,
+with a trailing newline.
+.TP
+boolean
+\fBtput\fR simply sets the exit code
+(\fB0\fR for TRUE if the terminal has the capability,
+\fB1\fR for FALSE if it does not),
+and writes nothing to the standard output.
+.RE
+.PP
+Before using a value returned on the standard output,
+the application should test the exit code
+(e.g., \fB$?\fR, see \fBsh\fR(1)) to be sure it is \fB0\fR.
 (See the \fBEXIT CODES\fR and \fBDIAGNOSTICS\fR sections.)
 For a complete list of capabilities
 and the \fIcapname\fR associated with each, see \fBterminfo\fR(\*n).
@@ -68,22 +84,36 @@ variables \fBLINES\fR and \fBCOLUMNS\fR will be ignored,and the
 operating system will not be queried for the actual screen size.
 .TP
 \fIcapname\fR
-indicates the attribute from the \fBterminfo\fR database.  When
+indicates the capability from the \fBterminfo\fR database.  When
 \fBtermcap\fR support is compiled in, the \fBtermcap\fR name for
-the attribute is also accepted.
+the capability is also accepted.
 .TP
 \fIparms\fR
-If the attribute is a string that takes parameters, the arguments
-\fIparms\fR will be instantiated into the string.  An all numeric
-argument will be passed to the attribute as a number.
+If the capability is a string that takes parameters, the arguments
+\fIparms\fR will be instantiated into the string.
+.IP
+Most parameters are numbers.
+Only a few terminfo capabilities require string parameters;
+\fBtput\fR uses a table to decide which to pass as strings.
+Normally \fBtput\fR uses \fBtparm\fR (3X) to perform the substitution.
+If no parameters are given for the capability,
+\fBtput\fR writes the string without performing the substitution.
 .TP
 \fB-S\fR
 allows more than one capability per invocation of \fBtput\fR.  The
 capabilities must be passed to \fBtput\fR from the standard input
-instead of from the command line (see example).  Only one
-\fIcapname\fR is allowed per line.  The \fB-S\fR option changes the
+instead of from the command line (see example).
+Only one \fIcapname\fR is allowed per line.
+The \fB-S\fR option changes the
 meaning of the \fB0\fR and \fB1\fR boolean and string exit codes (see the
 EXIT CODES section).
+.IP
+Again, \fBtput\fR uses a table and the presence of parameters in its input
+to decide whether to use \fBtparm\fR (3X),
+and how to interpret the parameters.
+.TP
+\fB-V\fR
+reports the version of ncurses which was used in this program, and exits.
 .TP
 \fBinit\fR
 If the \fBterminfo\fR database is present and an entry for the user's
@@ -110,6 +140,10 @@ user's terminal exists (see \fB-T\fR\fItype\fR above), then the long name
 of the terminal will be put out.  The long name is the last
 name in the first line of the terminal's description in the
 \fBterminfo\fR database [see \fBterm\fR(5)].
+.PP
+If \fBtput\fR is invoked by a link named \fBreset\fR, this has the
+same effect as \fBtput reset\fR.
+See \fBtset\fR for comparison, which has similar behavior.
 .SH EXAMPLES
 .TP 5
 \fBtput init\fR
@@ -117,7 +151,7 @@ Initialize the terminal according to the type of
 terminal in the environmental variable \fBTERM\fR.  This
 command should be included in everyone's .profile after
 the environmental variable \fBTERM\fR has been exported, as
-illustrated on the \fBprofile\fR(4) manual page.
+illustrated on the \fBprofile\fR(5) manual page.
 .TP 5
 \fBtput -T5620 reset\fR
 Reset an AT&T 5620 terminal, overriding the type of
@@ -149,11 +183,15 @@ Set exit code to indicate if the current terminal is a hard copy terminal.
 \fBtput cup 23 4\fR
 Send the sequence to move the cursor to row 23, column 4.
 .TP 5
+\fBtput cup\fR
+Send the terminfo string for cursor-movement, with no parameters substituted.
+.TP 5
 \fBtput longname\fR
 Print the long name from the \fBterminfo\fR database for the
 type of terminal specified in the environmental
 variable \fBTERM\fR.
-.TP 0
+.PP
+.RS 5
 \fBtput -S <<!\fR
 .br
 \fB> clear\fR
@@ -163,76 +201,93 @@ variable \fBTERM\fR.
 \fB> bold\fR
 .br
 \fB> !\fR
+.RE
 .TP 5
 \&
-This example shows tput processing several capabilities in one
-invocation.  This example clears the screen, moves the cursor to
-position 10, 10 and turns on bold (extra bright) mode.  The list is
-terminated by an exclamation mark (\fB!\fR) on a line by itself.
+This example shows \fBtput\fR processing several capabilities in one invocation.
+It clears the screen,
+moves the cursor to position 10, 10
+and turns on bold (extra bright) mode.
+The list is terminated by an exclamation mark (\fB!\fR) on a line by itself.
 .SH FILES
 .TP
 \fB\*d\fR
 compiled terminal description database
 .TP
-\fB/usr/include/curses.h\fR
-\fBcurses\fR(3X) header file
-.TP
-\fB/usr/include/term.h\fR
-\fBterminfo\fR header file
-.TP
 \fB@DATADIR@/tabset/*\fR
 tab settings for some terminals, in a format
 appropriate to be output to the terminal (escape
 sequences that set margins and tabs); for more
 information, see the "Tabs and Initialization"
-section of \fBterminfo\fR(4)
-.SH SEE ALSO
-\fBclear\fR(1), \fBstty\fR(1), \fBtabs\fR(\*n).  \fBprofile\fR(\*n),
-\fBterminfo\fR(4) in the \fISystem\fR \fIAdministrator\fR'\fIs\fR
-\fIReference\fR \fIManual\fR.  Chapter 10 of the
-\fIProgrammer\fR'\fIs\fR \fIGuide\fR.
+section of \fBterminfo\fR(5)
 .SH EXIT CODES
-If \fIcapname\fR is of type boolean, a value of \fB0\fR is set for
-TRUE and \fB1\fR for FALSE unless the \fB-S\fR option is used.
-
-If \fIcapname\fR is of type string, a value of \fB0\fR is set if the
-\fIcapname\fR is defined for this terminal \fItype\fR (the value of
-\fIcapname\fR is returned on standard output); a value of \fB1\fR is
-set if \fIcapname\fR is not defined for this terminal \fItype\fR (a
-null value is returned on standard output).
-
-If \fIcapname\fR is of type boolean or string and the \fB-S\fR option
-is used, a value of \fB0\fR is returned to indicate that all lines
-were successful.  No indication of which line failed can be given so
+If the \fB-S\fR option is used,
+\fBtput\fR checks for errors from each line,
+and if any errors are found, will set the exit code to 4 plus the
+number of lines with errors.
+If no errors are found, the exit code is \fB0\fR.
+No indication of which line failed can be given so
 exit code \fB1\fR will never appear.  Exit codes \fB2\fR, \fB3\fR, and
 \fB4\fR retain their usual interpretation.
-
-If \fIcapname\fR is of type integer, a value of \fB0\fR is always set,
+If the \fB-S\fR option is not used,
+the exit code depends on the type of \fIcapname\fR:
+.RS 5
+.TP
+.I boolean
+a value of \fB0\fR is set for TRUE and \fB1\fR for FALSE.
+.TP
+.I string
+a value of \fB0\fR is set if the
+\fIcapname\fR is defined for this terminal \fItype\fR (the value of
+\fIcapname\fR is returned on standard output);
+a value of \fB1\fR is set if \fIcapname\fR
+is not defined for this terminal \fItype\fR
+(nothing is written to standard output).
+.TP
+.I integer
+a value of \fB0\fR is always set,
 whether or not \fIcapname\fR is defined for this terminal \fItype\fR.
 To determine if \fIcapname\fR is defined for this terminal \fItype\fR,
-the user must test the value of standard output.  A value of \fB-1\fR
+the user must test the value written to standard output.
+A value of \fB-1\fR
 means that \fIcapname\fR is not defined for this terminal \fItype\fR.
-
+.TP
+.I other
+\fBreset\fR or \fBinit\fR may fail to find their respective files.
+In that case, the exit code is set to 4 + \fBerrno\fR.
+.RE
+.PP
 Any other exit code indicates an error; see the DIAGNOSTICS section.
 .SH DIAGNOSTICS
 \fBtput\fR prints the following error messages and sets the corresponding exit
 codes.
-
+.PP
+.ne 15
 .TS
 l l.
 exit code      error message
-\fB0\fR        (\fIcapname\fR is a numeric variable that is not specified in the
-       \fBterminfo\fR(\*n) database for this terminal type, e.g.
-       \fBtput -T450 lines\fR and \fBtput -T2621 xmc\fR)
+=
+\fB0\fR        T{
+(\fIcapname\fR is a numeric variable that is not specified in the
+\fBterminfo\fR(\*n) database for this terminal type, e.g.
+\fBtput -T450 lines\fR and \fBtput -T2621 xmc\fR)
+T}
 \fB1\fR        no error message is printed, see the \fBEXIT CODES\fR section.
 \fB2\fR        usage error
 \fB3\fR        unknown terminal \fItype\fR or no \fBterminfo\fR database
 \fB4\fR        unknown \fBterminfo\fR capability \fIcapname\fR
+\fB>4\fR       error occurred in -S
+=
 .TE
 .SH PORTABILITY
 The \fBlongname\fR and \fB-S\fR options, and the parameter-substitution
 features used in the \fBcup\fR example, are not supported in BSD curses or in
 AT&T/USL curses before SVr4.
+.SH SEE ALSO
+\fB@CLEAR@\fR(1),
+\fBstty\fR(1),
+\fBtabs\fR(\*n),
+\fBterminfo\fR(5).
 .\"#
 .\"# The following sets edit modes for GNU EMACS
 .\"# Local Variables: